PM-9000GTA Multiparameter Patient Monitor Hospital Ambulance Instrument

Brand Name : Rainbow

Model Number : PM-9000GTA NEW

Certification : ISO13485

Place of Origin : China

MOQ : 1 unit

Price : US $285.0 - 400.0

Payment Terms : L/C, T/T, Western Union, MoneyGram

Supply Ability : 30000units/year

Delivery Time : Within 3 days

Packaging Details : Packing terms: Anti-collision film+ Carton box Carton box : 40*30*35cm Gross weight: 5kg

Warranty : 1 year

Power Source : Electric

Material : Plastic

Quality Certification : ce

Instrument classification : Class II

Type : First-Aid Devices

Dimension : 37*28*35cm

Weight : 3.4Kg

Power supply : AC/DC

Application : All-round monitor for adult, pediatric and neonate

Standard parameters : ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP

Display : 12.1'' color TFT LCD

Contact Now

New Design PM-9000GTA Multiparameter Patient Monitor Hospital Ambulance Instrument Portable Vital Sign Monitor

PM-9000GTA Multiparameter Patient Monitor Hospital Ambulance InstrumentPM-9000GTA Multiparameter Patient Monitor Hospital Ambulance InstrumentPM-9000GTA Multiparameter Patient Monitor Hospital Ambulance Instrument

The monitor has abundant functions that can be used for clinical monitoring with adult, pediatric and neonate. Users may select different parameter configuration according to different requirements. The monitor, power supplied by 100-240V~,50/60Hz.

Features

1. 3/5 lead ECG, suppot 7 ECG waveforms
Unique accessory box design
2. Excellent ECG Anti-ESU, anti- defibrillator performance
3. Unique NIBP algorithm keep accuracy in all kinds of patient conditions
4. SpO2 have DSP algorithm and excellent performance when movement;
5. 720 hours trend data and 2 hours wave data
6. USB data output with software to view data on computer
7. 7 screen layouts: Standard, BigFont, Trend, OxyCRG, ECG Full-lead, OtherBed;
8. Dynamic screen setting, every parameters and waveforms can set open or closed and set color
9. USB data output with software to view data on computer
10. Suport 16 languages include: English, French, German, Spanish, Portuguese, Russian and etc
11. Unique human voice alarm
12. USB WIFI module can easy connect to CMS

Function

• ECG Measurement
Leads choices:All,L.I, III, aVF, aVR. aVL.V1--6chest leads showed Gains options: x1, ×2,×0.25, and ×0.5 four trenches
Frequency:0.5 Hz- 100 Hz
Common-mode signal inhibition More than 70 dB
Scan rate:12.5 mm / S, 25 mm / $,50 mm / S standard three stalls.
Heart rate accuracy: 1 + per minute
Precision calibration signal: 1m(peak, +3% accuracy)
ST Detection: measurement range(-1.0mV-..-+1.0mV)
Using Standard: meet the ANSI/ AMI EC13 - 2002 standard
Response time: 1s
Alarm: Sound and Light
Preset heart rate range: (Alarmover preset numerical)
Upper limit: 17-300 bpm adjustabl
Lower limit: 15-298 bpm adjustable

• NIBP Measurement
Technique: Oscilloscopic
Measurement unit: mmHg/Kpa
Overvoltage protection: Double safety protection
One measurement time: less than 45S
Pressure range within the cuff: 0-300mmg
Blood pressure measurement accuracy: AnS/AAMI SP10-2002 standard specifies the average error and standard deviation values
Initial cuff inflation: 160mmg (120mmlg for children)
Inflation of the cuff. original systolic blood pressure + 30 mmHg
Blood pressure measurement range and error
Systolic blood pressure 40 mmH - 280 mmHg
Average pressure 20 mmg - 240 mmlg
Diastolic pressure 10 mg to 220 mmHg
Blood pressure measurement error: = 1.1Ka (=8mmHg) or $10%
whichever is greater
Response time: 15
Alarm mode: sound and light alarm
Alarm range and error: (alarm exceeding preset value)
Systolic blood pressure up to 42mmg - 280 mmHg
Lower limit 40 mmHg to 278 mmHg
Diastolic pressure Upper limit 12 mmg - 220 mmHg
Lower limits are 10 mmHg to 218 mmHg
Alarm error: #1 mmHg
Standard of use: Complies with THE ANSI/AAMI SP10-2002 standard

• SPO2 Measurement
Range: 0-100%
Accuracy: 1%
Resolution: 1%
Pulse count: 20-250 beats/min
Response time: 15
Alarm mode: sound and light alarm
Alarm range and error: (alarm exceeding preset value)
Upper limit 1%-100%
Lower limit 0% -99%

• TEMP Measurement
Technology: Highly sensitive thermistor probe
Body temperature measurement range: 0°C - - 50°C
Resolution: 0.1%
Body temperature accuracy: $1°C
Response time: 15
Alarm mode: sound and light alarm
Alarm range and error: (exceed the preset value alarm)
Alarm error: +1°C

RESP Breathe
Respiratory rate range: 0-60 breaths/min
Accuracy: 11rpm
Response time: 1S
Gain options: ×1, ×2, ×4, and 0.5 four trenches
Alarm mode: sound and light alarm
Alarm range and error: (exceed the preset value alarm)
The upper limit is adjustable between 8-120 times/min
The upper limit is adjustable between 7-119 times/min
Alarm error: ± 1rpm

Accessories

1)Adult fingertip SpO2 probe (5-pin)
2)Adult NIBP cuff
3)NIBP extension tube
4)ECG lead cable
5)ECG electrode
6)Temperature probe
7)Power cord
8)Ground wire
9)User Manual

PM-9000GTA Multiparameter Patient Monitor Hospital Ambulance InstrumentPM-9000GTA Multiparameter Patient Monitor Hospital Ambulance Instrument


Product Tags:

Hospital Multiparameter Patient Monitor

      

PM-9000GTA Vital Sign Monitor

      

RESP Multiparameter Patient Monitor

      
Wholesale PM-9000GTA Multiparameter Patient Monitor Hospital Ambulance Instrument from china suppliers

PM-9000GTA Multiparameter Patient Monitor Hospital Ambulance Instrument Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hunan Province Rainbow Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)